Safety Encapsulated Transformer

In 2011 The Enerdoor Group acquired Eichhoff Elektroa Hungarian company established in 1989.  Eichhoff is known throughout Europe for high quality innovative solutions for safety encapsulated transformers, electronic ignition systems, and ignition transformers.   

Enerdoor safety transformers are important elements for an interference-free current supply and guarantee long lasting function of equipment. This extensive line includes small transformers and safety transformers of various designs with various mounting and connection options with performance data up to 100 VA. The potted transformers are produced on automated manufacturing systems.  

Eichhoff is an ISO 9001 Certified manufacturer with the majority of products being UL recognized and VDE approved. These products are made for the international market and sold throughout the United States, Europe, and Asia.

To view the full transformer brochure, please click here.

EE 20

  • Primary voltage 115 - 480 Vac
  • Secondary voltage from 3 - 24V
  • Output power up to 0.6 VA
  • Primary and secondary voltage and pin configuration on request
  • Safety class II

EI 30

  • Primary voltage 115 - 480 Vac
  • Secondary voltage from 3 - 24V
  • Output power up to 4.8 VA
  • Primary and secondary voltage and pin configuration on request
  • Safety class II
  • Two chamber bobbin

EI 38

  • Primary voltage 115 - 480 Vac
  • Secondary voltage from 3 - 24V
  • Output power up to 6 VA
  • Primary and secondary voltage and pin configuration on request
  • Safety class II
  • Two chamber bobbin

EI 42

  • Primary voltage 115 - 480 Vac
  • Secondary voltage from 3 - 24V
  • Output power up to 6 VA
  • Primary and secondary voltage and pin configuration on request
  • Safety class II
  • Two chamber bobbin

EI 48

  • Primary voltage 115 - 480 Vac
  • Secondary voltage from 3 - 24V
  • Output power up to 13 VA
  • Primary and secondary voltage and pin configuration on request
  • Safety class II
  • Two chamber bobbin

EI 54

  • Primary voltage 115 - 480 Vac
  • Secondary voltage from 3 - 24V
  • Output power up to 20.5 VA
  • Primary and secondary voltage and pin configuration on request
  • Safety class II
  • Two chamber bobbin

EI 60

  • Primary voltage 115 - 480 Vac
  • Secondary voltage from 3 - 24V
  • Output power up to 30 VA
  • Primary and secondary voltage and pin configuration on request
  • Safety class II
  • Two chamber bobbin

EI 66

  • Primary voltage 115 - 480 Vac
  • Secondary voltage from 3 - 24V
  • Output power up to 63 VA
  • Primary and secondary voltage and pin configuration on request
  • Safety class II
  • Two chamber bobbin

EI 84

  • Primary voltage 115 - 480 Vac
  • Secondary voltage from 3 - 24V
  • Output power up to 100 VA
  • Primary and secondary voltage and pin configuration on request
  • Safety class II
  • Two chamber bobbin

UI 30

  • Primary voltage 115 - 250 Vac
  • Secondary voltage from 3 - 24V
  • Output power up to 10 VA
  • Primary and secondary voltage and pin configuration on request
  • Safety class II
  • Two chamber bobbin

UI 39

  • Primary voltage 115 - 250 Vac
  • Secondary voltage from 3 - 24V
  • Output power up to 32 VA
  • Primary and secondary voltage and pin configuration on request
  • Safety class II
Enerdoor Facebook Linked In Google+ Youtube
Web Site Design and Hosting by Saco Design | Powered by Site Avenger CMS